We started off by transformating with our IbpB – RFP and ROSE – RFP parts to our TOP10 E. coli. We applied the procedure and finally finished off the transformation steps. The next day we took our plates and observed that there were colonies in both IbpB and ROSE however only IbpB was colored red but ROSE was white. | We started off by transformating with our IbpB – RFP and ROSE – RFP parts to our TOP10 E. coli. We applied the procedure and finally finished off the transformation steps. The next day we took our plates and observed that there were colonies in both IbpB and ROSE however only IbpB was colored red but ROSE was white. | ||
+ | |||
+ | <html><img src="https://static.igem.org/mediawiki/2013hs/b/b5/AUC_Turkey_PLATEzz.jpg"/></html> | ||
Then we acquired the electrophoresis results, and as it can be seen below, both of the parts were the right base length. The IbpB – RFP part is 917 base pairs in total and ROSE – RFP is 902 base pairs. According to the base length of these parts, the cloning was successful. | Then we acquired the electrophoresis results, and as it can be seen below, both of the parts were the right base length. The IbpB – RFP part is 917 base pairs in total and ROSE – RFP is 902 base pairs. According to the base length of these parts, the cloning was successful. | ||
- | + | <html><img src="https://static.igem.org/mediawiki/2013hs/7/77/09.06.2013.tif"/></html> | |
==Step 2: Liquid Culture Examination== | ==Step 2: Liquid Culture Examination== | ||
Line 20: | Line 22: | ||
We centrifuged the cultures at 14,000 rpm and acquired the result as you can see below. In this, the IbpB and RFP came out as red however the ROSE part didn’t turn out red. This showed that our IbpB part was correctly showing RBS properties but the ROSE Thermometer didn’t work. | We centrifuged the cultures at 14,000 rpm and acquired the result as you can see below. In this, the IbpB and RFP came out as red however the ROSE part didn’t turn out red. This showed that our IbpB part was correctly showing RBS properties but the ROSE Thermometer didn’t work. | ||
- | <html><img src="https://static.igem.org/mediawiki/2013hs/ | + | <html><img src="https://static.igem.org/mediawiki/2013hs/d/d9/AUC_Turkey_Home_Project.png" /></html> |
==Step 3: Examination in Variable Temperatures== | ==Step 3: Examination in Variable Temperatures== | ||
Line 33: | Line 35: | ||
Through examining the pellets of the cultures, we have reached the consensus that our IbpB Thermometer is temperature sensitive and also shows RBS properties however shows slightly less RBS functionality when compared to the RBS of RFP, B0034. | Through examining the pellets of the cultures, we have reached the consensus that our IbpB Thermometer is temperature sensitive and also shows RBS properties however shows slightly less RBS functionality when compared to the RBS of RFP, B0034. | ||
+ | |||
+ | <html><img src="https://static.igem.org/mediawiki/2013hs/4/49/AUC_Turkey_asdsasasfawefawdefa.jpg"/></html> | ||
==Step 4: Cultures Under Biored== | ==Step 4: Cultures Under Biored== | ||
Line 46: | Line 50: | ||
*The IbpB Thermometer is a weaker RBS than B0034. | *The IbpB Thermometer is a weaker RBS than B0034. | ||
- | <html><img src="https://static.igem.org/mediawiki/2013hs/6/61/AUC_Turkey_Step3.png" /></html> | + | <html><img src="https://static.igem.org/mediawiki/2013hs/6/61/AUC_Turkey_Step3.png" /><br/><img src="https://static.igem.org/mediawiki/2013hs/8/81/AUC_turkey_qeqw.jpg"/></html> |
==Step 5: Fluorescent Microscope== | ==Step 5: Fluorescent Microscope== | ||
Line 53: | Line 57: | ||
Through taking advantage of the fact that there is extra glowing in RFP containing bacteria, we calculated the difference in red light exposure and prepared them as quantitative data through the use of computer programs. | Through taking advantage of the fact that there is extra glowing in RFP containing bacteria, we calculated the difference in red light exposure and prepared them as quantitative data through the use of computer programs. | ||
+ | |||
+ | <html><table style="text-align:center; background:transparent; border-spacing:5px;"><tr><td><img src="https://static.igem.org/mediawiki/2013hs/d/d3/AUC_Turkey_Res_1.jpg"/><br/>RFP 42 C % 40.39</td><td><img src="https://static.igem.org/mediawiki/2013hs/4/47/AUC_Turkey_Res_2.jpg"/><br/>RFP 25 C % 34.67</td></tr><tr><td><img src="https://static.igem.org/mediawiki/2013hs/0/00/AUC_Turkey_Res_3.jpg"/><br/>IbpB 42 C % 35.22</td><td><img src="https://static.igem.org/mediawiki/2013hs/d/d2/AUC_Turkey_Res_4.jpg"/><br/>IbpB 25 C % 16.71</td></tr></table></html> |