<td>June 14th</td>
<td>June 14th</td>
-
<td>We recorded the results from yesterday, then we did colony PCR on the colonies, choosing the ligation mixture that was a 2:1 ratio of HybB to backbone. We did a diagnostic gel with 16 colonies and analyzed our results. Unfortunately, we did not put the colonies in the thermocycler for long enough, so our colony PCR failed.</td>
+
<td>We recorded the results from yesterday, then we did colony PCR on the colonies, choosing the ligation mixture that was a 2:1 ratio of HybB to backbone. We did a diagnostic gel with 16 colonies and analyzed our results. Unfortunately, our colony PCR failed. We do not know the reason for the failure, but we suspect that
 +
 
 +
a)we did not put the colonies in the thermocycler for long enough, or
 +
b)the cells did not contain our part. </td>
</tr>
</tr>
<tr>
<tr>

Revision as of 14:39, 17 June 2013